“INFO-SOLO-01” display panel.
Description:
“INFO-SOLO-01” display panel.
Purpose:
“INFO-SOLO-01” display panel is meant for indication of the gamma-radiation dose ambient equivalent intensity obtained from “RKS-01GD-SOLO” gamma-radiation detecting unit.
Specification:
1. “INFO-SOLO-01” display panel
|
1. |
Equivalent dose intensity indication range, microsieverts per hour |
0.01...107 |
|
2. |
Real time indication error, no more than |
± 1 min per 100 h |
|
3. |
Quantity of digit positions for real time indication |
four |
|
4. |
Environment temperature indication range |
from -40°С to + 50°С |
|
5. |
Temperature indication error |
no more than ± 1°С within the range from -40°С to + 50°С |
|
6. |
Quantity of digit positions for temperature indication |
four |
|
7. |
Programmability for three threshold levels within the range |
from 0.01 microsieverts per hour to 9.99 sieverts per hour with 0.01 microsieverts discretization |
|
8. |
Threshold level crossing alarm |
sound (with various tones for each threshold level)
visual (change of flashing color) |
|
9. |
Adjustment of threshold (by means of a secret code) and time |
by means of a keyboard at the side plate of the panel
|
|
10. |
Networking |
via RS 485 interface |
|
11. |
Industrial mains power supply |
220 V through power adapter |
|
12. |
Operation mode |
round-the-clock, continuous |
|
13. |
Distance between the panel and detecting unit |
from 0.5 tо 50 m |
|
14. |
Dimensions |
no more than (800x140x50) mm |
|
15. |
Weight (without power adapter) |
no more than 2.3 kg |
|
16. |
Method of mounting |
vertical, wall-mounted |
2. “RKS-01GD-SOLO” gamma-radiation detecting unit.
|
1. |
Range of gamma-radiation dose ambient equivalent intensity and relative basic error |
0.01 microsieverts per hour …10 sieverts per hour; ±15% (0.01 microsieverts per hour …100 sieverts per hour – custom-made) |
|
2. |
Energy range of detectable gamma-radiation, energy dependence |
0.05…3.0 MeV
|
|
3. |
Detecting unit’s operation mode setting time |
no more than 1 min |
|
4. |
Rated voltage of detecting unit power supply from an external power source |
5(7÷15) V |
|
5. |
Absorbed current of the detecting unit for the entire range of gamma-radiation equivalent dose intensity, no more than |
30 mА |
|
6. |
Range of operating temperatures |
-40°С …+60°С |
|
7. |
Weight of the detecting unit without mounting components |
no more than 0.5 kg |
|
8. |
Dimensions of the detecting unit without mounting components |
no more than 160x60 mm |
3. Scope of supply.
|
1. |
“INFO-SOLO-01” display panel. |
|
2. |
“RKS-01GD-SOLO” gamma-radiation detecting unit. |
|
3. |
Connecting cable. |
|
4. |
220V mains power adapter. |
|
5. |
Operation manual. |
|
6. |
Package. |
Warranty service 12 months;
Service: During the entire lifetime.
www.solo.kz e-mail: info@solo.kz, om@solo.kz