Solo Ltd. Quality, experience, reliability

MULTI-PURPOSE RADIOMETER RKS-01-SOLO

Description:

RKS-01-SOLO

MULTI-PURPOSE RADIOMETER "RKS-01-SOLO"

This dosimeter is designed for complex radiation control over environment, work places, installations and transport facilities, scrap metal and other secondary raw materials. It has a broad range of highly sensitive blocks of alpha-, beta-, gamma- (include the X-ray range) and neutron-emanations. It is completed depending on the customer's demand.

The instrument is provided with a convenient survey mode for special automatic control of luggage and vehicles, including a possible presence of shielding investigating objects.

It is also provided with the convenient liquid-crystal indicator - search operation arrow mode, visual and acoustic alarm system.

The instrument is entered into the RK State Register as No. KZ.02.02.00335-2004

The alignment of energy dependence non-linearity of scintillators' sensitivity is performed by means of the analog-to-digital converter. The instrument ensures the implementation of radiation control general tasks in accordance with the Radiation Safety Regulations-99 and other normative documents.

PECULIARITIES:

convenient liquid-crystal indicator-arrow mode of search operation;

estimation of a measured radionuclides spectral composition by means of a built-in analog-to-digital converter;

PC-link using standard communication interface for data transmission;

small sizes and lightweight of the instrument.

Basic characteristics

This instrument consists of the control panel and detachable detectors.

Alpha and Beta Particles Detecting Block:

A scintillation detector, with an area of 40 cm2 is installed in the detecting block.

The range of flux density measurements is:

alpha particle, particles/ minute×cm2, from 0.1 to 105

beta particle, particles/ minute×cm2, from 1 to 105

The energy range is: for alpha particles, MeV, from 3 to 8

for beta particles, MeV, from 0.06 to 3.5

The limit of a permissible basic relative error in measurements is 20%

The overall size of the detector:

Diameter, mm 88

Long, mm 220

Weight, kg, not more than 0.4

Gamma-radiation Detecting block:

A scintillation detecting block

The range of gamma- radiation energies is from 20 keV to 10 MeV

The Measurement range:

of equivalent dose rate, mSv/hr 0.01-3x102

of equivalent dose, mSvr 0.1-1x108

The limit of a permissible basic relative error in measurements is: ±15%

The Detector overall size:

Diameter, mm 38

Long, mm 215, (270)

Weight, kg, not more than 0.5

Gas discharge detecting block

The range of gamma- radiation energies is from 40 keV to 10 MeV

The Measurement range:

of equivalent dose rate, mSv/hr 1х102 to 1х106

of equivalent dose, mSvr 0.1 to 1х108

The limit of a permissible basic relative error in measurements is:

±20%

The Detector overall size:

Diameter, mm 80

Long, mm 90

Weight, kg not more than 0.3

Continuous and Pulse X-ray Radiation Detecting Block

A scintillation detector

The range of energies:

For organic 14 keV to 1.0 MeV

For non-organic 5 keV to 1.0 MeV

The Measurement range for organic scintillator:

of equivalent dose rate, mSv/hr 0.05 to 1 х 106

with a shielding screen up to 40.0 Sv/hr

of equivalent dose, mSvr 0.1 to 1 х 108

The limit of a permissible basic relative error in measurements is: ±20%

The Detector overall size:

Diameter, mm 40

Long, mm 230

Weight, kg, not more than 0.5

Neutron radiation detecting block

Detecting block is gas-discharge He3(B10)

The energy range for neutrons is

eV to 10 MeV

The Measurement range:

of equivalent dose rate, mSv/hr 0.1 to 1 x 105

of equivalent dose, mSvr 0.1 to 1 x 108

The limit of a permissible basic relative error in measurements is: ±20%

The Detector overall size:

Diameter, mm 38

Long, mm 300, (200)

Weight, kg not more than 0.5

The moderator of neutrons overall size:

Diameter, mm 76

Long, mm 140, (60)

Weight, kg, not more than 2.0 (0.5)

Control Panel

The operating range of the control panel and detecting blocks is, 0С, from -40 to +50

For voice accompaniment and data recording in memory, 0С, from -40 to +50

With information output to a liquid crystal display, 0С, from -30 to +50

Power supply is

an internal lithium-ion battery, with a voltage of 7,2 V or through a mains adapter with an output voltage of 12 V which is included into the package

The period of continuous operation with a discharged battery is, hours, at least 24

The number of charge/discharge cycles is at least 1000

The control panel overall size, mm 200 х 120 х 100

The control panel weight, kg, does not exceed 1.0

On the customer's demand "RKS-01-SOLO" may be completed with a PC and software (developed for Windows) supplied on a СD carrier.

Warranty service 12 months;

Service: During the entire lifetime.

www.solo.kz e-mail: info@solo.kz, om@solo.kz




Reviews on this model

Write your comment


CAPTCHA Send